Title :
Improvement of accuracy in large sewer mean flow measurements using an array of Doppler transducers
Author :
Hughes, A.W. ; Longair, I.M.
Author_Institution :
Abertay Univ., Dundee, UK
fYear :
1996
fDate :
35173
Firstpage :
42552
Lastpage :
42556
Abstract :
The objective of the work was to produce a self-controlled, battery powered instrument that could produce velocity profile information across the section of a large sewer. The Doppler Transducer Velocity Array System was produced to meet this and testing has shown that the system functions as designed. Field testing of the system showed that the accuracy of the results recorded was to within 10.9% of an independent propeller meter. The transducer beams were forced to cross at specific positions and thus it was known exactly where in the flow the velocity readings originated
Keywords :
Doppler measurement; flow measurement; flowmeters; ultrasonic applications; ultrasonic transducer arrays; 3D representation; Doppler transducer velocity array system; US transducer; battery powered instrument; crossed transducer beams; field testing; improved accuracy; large sewer; mean flow measurements; multiple velocity measurements; self-controlled; storm data; weighted averaging;