  • Abstract
    In this paper, a vector-less simple technique based on the oscillation-test strategy (OTS) is proposed for the test of the Buck regulator. In the test mode, the circuit under test (CUT) of the buck regulator could be easily transformed into an oscillator for generating the oscillating signal. By observing the frequency and amplitude of the oscillating signal, we could detect the CUT to see if it is faulty or fault-free. Simulation results show that the fault coverage for hard faults could reach up to 99%. Based on the facts of the simple structure and high fault coverage, OTS is considered as a useful technique in the testing of the Buck regulator.
  • Keywords
    circuit oscillations; fault diagnosis; power convertors; voltage regulators; buck voltage regulator; circuit under test; fault diagnosis; oscillating signal; oscillation test technique; Circuit faults; Circuit testing; Electrical fault detection; Fault detection; Frequency; Oscillators; Regulators; Signal detection; Signal generators; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Applied Power Electronics Conference and Exposition (APEC), 2010 Twenty-Fifth Annual IEEE
  • Conference_Location
    Palm Springs, CA
  • ISSN
    1048-2334
  • Print_ISBN
    978-1-4244-4782-4
  • Electronic_ISBN
    1048-2334
  • Type

    conf

  • DOI
    10.1109/APEC.2010.5433374
  • Filename
    5433374