Oscillation-test technique for Buck voltage regulator
Author
Huang, Jing-Yi ; Wu, Chun-Hsun ; Chang-Chien, Le-Ren ; Chang, Soon-Jyh
Author_Institution
Dept. of Electr. Eng., Nat. Cheng-Kung Univ., Tainan, Taiwan
fYear
2010
fDate
21-25 Feb. 2010
Firstpage
1043
Lastpage
1047
Abstract
In this paper, a vector-less simple technique based on the oscillation-test strategy (OTS) is proposed for the test of the Buck regulator. In the test mode, the circuit under test (CUT) of the buck regulator could be easily transformed into an oscillator for generating the oscillating signal. By observing the frequency and amplitude of the oscillating signal, we could detect the CUT to see if it is faulty or fault-free. Simulation results show that the fault coverage for hard faults could reach up to 99%. Based on the facts of the simple structure and high fault coverage, OTS is considered as a useful technique in the testing of the Buck regulator.
Keywords
circuit oscillations; fault diagnosis; power convertors; voltage regulators; buck voltage regulator; circuit under test; fault diagnosis; oscillating signal; oscillation test technique; Circuit faults; Circuit testing; Electrical fault detection; Fault detection; Frequency; Oscillators; Regulators; Signal detection; Signal generators; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Applied Power Electronics Conference and Exposition (APEC), 2010 Twenty-Fifth Annual IEEE
Conference_Location
Palm Springs, CA
ISSN
1048-2334
Print_ISBN
978-1-4244-4782-4
Electronic_ISBN
1048-2334
Type
conf
DOI
10.1109/APEC.2010.5433374
Filename
5433374
Link To Document