DocumentCode :
1876395
Title :
Selective active filter with remote harmonic distortion control
Author :
Casaravilla, Gonzalo ; Salvia, Adriana ; Briozzo, Cesar ; WATANABE, EDSON
Author_Institution :
IIE, UDELAR, Uruguay
Volume :
2
fYear :
2002
fDate :
6-9 Oct. 2002
Firstpage :
478
Abstract :
This paper presents the calculation methods for the different filtering blocks of a selective active filter in order to minimize the active filter inverter size, keeping the harmonic emissions at the limits stated by the applicable regulations. Since it may be necessary to comply with the regulations at a remote place with respect to the active filter location, the method has been extended to this case. In order to validate the simulations, measurements which were made at a real application - and arc furnace - were used. Finally, the simulated results obtained with a remote hybrid filter were compared with those obtained when an active filter is installed directly at the place where the harmonic emission regulations must be met. The comparison shows that remote compensation is an alternative to be seriously considered. The results are similar to those obtained with local compensation and the cost may be substantially lower.
Keywords :
active filters; harmonic distortion; power harmonic filters; power supply quality; active filter; active filter inverter size; arc furnace; filter blocks; harmonic distortion control; harmonic emission; power quality; remote hybrid filter; Active filters; Costs; Current measurement; Distortion measurement; Filtering; Frequency; Harmonic distortion; Inverters; Power harmonic filters; Total harmonic distortion;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Harmonics and Quality of Power, 2002. 10th International Conference on
Print_ISBN :
0-7803-7671-4
Type :
conf
DOI :
10.1109/ICHQP.2002.1221482
Filename :
1221482
Link To Document :
بازگشت