  • Abstract
    The CANDELA photo-injector is a two cell S-band photo-injector. The dispenser photocathode is illuminated by a 500 fs pulse from a frequency-tripled Ti:sapphire laser. In this paper we report charge measurements showing that the dispenser photocathode has a quantum efficiency as high as 10-3. This efficiency decreases with a lifetime of 12 hours, but can be recovered by heating the cathode for 5 minutes
  • Keywords
    accelerator RF systems; electron guns; electron sources; particle beam injection; photocathodes; 12 h; 3 GHz; 5 min; 500 fs; CANDELA photo-injector; S-band photo-injector; Ti:Al2O3; charge measurements; dispenser photocathode; frequency-tripled Ti:sapphire laser; lifetime; quantum efficiency; Barium; Calcium; Cathodes; Copper; Heating; Laser modes; Optical pulses; Radio frequency; Springs; Tungsten;