Title : 
Phase-scan analysis results for the first drift tube linac module in the Ground Test Accelerator: data reproducibility and comparison to simulations
         
        
            Author : 
Johnson, K.F. ; Sander, O.R. ; Bolme, G.O. ; Bowling, S. ; Connolly, R. ; Gilpatrick, J.D. ; Lysenko, W.P. ; Power, J. ; Wadlinger, E.A. ; Yuan, V.
         
        
            Author_Institution : 
Los Alamos Nat. Lab., NM, USA
         
        
        
        
        
        
            Abstract : 
The Ground Test Accelerator (GTA) had the objective of producing a high-brightness, high-current H- beam. The major accelerator components were a 35 keV injector, a Radio Frequency Quadrupole, an intertank matching section, and a drift tube linac (DTL), consisting of 10 modules. This paper discusses the phase-scan technique which was used to experimentally determine the rf operating parameters for the commissioning and routine operation of the first DTL module
         
        
            Keywords : 
accelerator cavities; ion accelerators; particle beam dynamics; 35 keV; Ground Test Accelerator; H; RF operating parameters; drift tube linac; drift tube linac module; high-brightness high-current H- beam; intertank matching section; phase-scan analysis results; phase-scan technique; Energy measurement; Life estimation; Linear particle accelerator; Particle beams; Phase measurement; Probes; RF signals; Reproducibility of results; Testing; Voltage;
         
        
        
        
            Conference_Titel : 
Particle Accelerator Conference, 1995., Proceedings of the 1995
         
        
            Conference_Location : 
Dallas, TX
         
        
            Print_ISBN : 
0-7803-2934-1
         
        
        
            DOI : 
10.1109/PAC.1995.505162