Title :
Lifetime experience with low temperature cathodes equipped in super power klystrons
Author_Institution :
Philips GmbH, Hamburg, Germany
Abstract :
When Philips started the production of super power klystrons in 1976 the electron emitter was a tungsten dispenser cathode of the well-known Philips “B” type. One disadvantage of this cathode type is the relative high cathode temperature. Many efforts have been spent from researchers world-wide to decrease the operating temperature of the dispenser cathode. Since 1990 we have tested several sputter coated Os/Ru cathodes in cw super power klystrons. The expected decrease of the temperature has been entirely confirmed. Measured emission data compared to “B” cathodes during factory acceptance test are presented. Positive experience concerning lifetime under real operation conditions has been gained at different international accelerator centers and will be reported
Keywords :
accelerator RF systems; cathodes; electron emission; klystrons; life testing; power supplies to apparatus; Os-Ru; dispenser cathode; electron emitter; emission data; factory acceptance test; lifetime experience; low temperature cathodes; sputter coated Os/Ru cathodes; super power klystrons; Assembly; Barium; Cathodes; Coatings; Electron emission; Klystrons; Optical surface waves; Production; Temperature; Tungsten;
Conference_Titel :
Particle Accelerator Conference, 1995., Proceedings of the 1995
Conference_Location :
Dallas, TX
Print_ISBN :
0-7803-2934-1
DOI :
10.1109/PAC.1995.505282