Abstract
The RHIC RF systems must capture the injected beam, accelerate it through transition to top energy, shorten the bunches prior to rebucketing, and store the beam for 10 hours in the presence of strong intra-beam scattering. These different functions are met by three independent systems. An accelerating system at 26.7 Mhz (h=342), a storage system at 196.1 MHz (h=2508), and a wideband system for the damping of injection errors
Keywords
accelerator RF systems; colliding beam accelerators; ion accelerators; storage rings; synchrotrons; 196.1 MHz; 26.7 MHz; RHIC RF systems; Relativistic Heavy Ion Collider; accelerating system; bunches; injection error damping; rebucketing; storage system; strong intra-beam scattering; wideband system; Acceleration; Colliding beam accelerators; Colliding beam devices; Gold; Particle beams; Protons; Radio frequency; Structural beams; Synchrotrons; Voltage;