Title :
A comparison of two injection line matching sections for compact cyclotrons
Author :
Kuo, T. ; Baartman, R. ; Root, L. ; Milton, B. ; Laxadal, R. ; Yuan, D. ; Jayamanna, K. ; Schmor, P. ; Dutto, G. ; Dehnel, M. ; Erdman, K.
Author_Institution :
TRIUMF, Vancouver, BC, Canada
Abstract :
Two versions of injection line matching sections between the external ion source and the spiral inflector are used for the compact cyclotrons developed at TRIUMF in cooperation with Ebco Technologies. The 30 MeV model adopts a solenoid-doublet (SQQ) version while the 19 MeV unit takes a four quadrupole/two quadrupole (4Q/2Q) option. Both cyclotrons use a same type of H cusp source and an identical inflector-central region combination. A comparison has been made between these two systems, in terms of DC transmission and RF acceptance as a function of source´s H current intensity and emittance. The design and optics characteristics for both systems are described and the results obtained are reported
Keywords :
beam handling equipment; beam handling techniques; cyclotrons; ion accelerators; ion optics; particle beam injection; 19 MeV; 30 MeV; DC transmission; H; H current intensity; RF acceptance; TRIUMF; compact cyclotrons; design; external ion source; four quadrupole/two quadrupole option; injection line matching sections; optics characteristics; solenoid-doublet version; spiral inflector; Cyclotrons; Ion sources; Isotopes; Optical design; Production systems; Radio frequency; Solenoids; Spirals; Stimulated emission; System testing;
Conference_Titel :
Particle Accelerator Conference, 1995., Proceedings of the 1995
Conference_Location :
Dallas, TX
Print_ISBN :
0-7803-2934-1
DOI :
10.1109/PAC.1995.505386