Abstract :
A general description of the slow extraction system of a charged particle beam from the Nuclotron is presented. The third integer resonance is used for the slow step-over extraction mechanism. The septum deflectors, that are an electrostatic septum and two superconducting Lambertson magnets, are the most complicated components of the Nuclotron slow extraction system. A detailed design of these elements based on computer simulation is considered. The septum deflectors are under construction and bench testing before their placement in the Nuclotron ring
Keywords :
ion accelerators; particle beam extraction; synchrotrons; Nuclotron; computer simulation; electrostatic septum; septum deflectors; slow extraction system; slow step-over extraction mechanism; superconducting Lambertson magnets; third integer resonance; Acceleration; Computer simulation; Electrostatics; Lenses; Particle beams; Power system reliability; Resonance; Structural beams; Superconducting magnets; Testing;