  • Abstract
    This paper describes the modeling of power-factor-correction converters under average-current-mode control. The approach employs a double averaging procedure, which first applies the usual averaging over the switching period and subsequently applies averaging over the mains period. The resulting model, after two averaging steps, is nonlinear and capable of describing the low-frequency nonlinear dynamics of the system. The parameter ranges within which stable operation is guaranteed can be accurately and easily found using this model.
  • Keywords
    electric current control; power factor correction; switched mode power supplies; switching convertors; PFC switching converter; average-current-mode control; double averaging procedure; low-frequency nonlinear dynamic; power-factor-correction converter; Control systems; Electric variables control; Force control; Nonlinear dynamical systems; Output feedback; Power system modeling; Shape control; Stability analysis; Switching converters; Voltage control;