DocumentCode :
1885333
Title :
Design and testing of a high power, ultra-high vacuum, dual-directional coupler for the Advanced Photon Source (APS) linear accelerator
Author :
Brauer, S.O. ; Grelick, A.E. ; Grimmer, J. ; Otocki, R.D. ; Kang, Y.W. ; Noonan, J. ; Russell, T.
Author_Institution :
Adv. Photon Source, Argonne Nat. Lab., IL, USA
Volume :
3
fYear :
1995
fDate :
1-5 May 1995
Firstpage :
2020
Abstract :
Leaks and cracks have developed in the vacuum windows of the linac WR 284 waveguide directional couplers. In the existing coupler design the vacuum window is brazed to the waveguide. Replacement of a cracked window requires the removal of the component from the waveguide system resulting in a loss of vacuum in the waveguide. A new design has been developed and a prototype tested that utilizes bolted-in vacuum windows and allows for easier replacement of the windows in the system, while still providing suitable radio-frequency specifications
Keywords :
accelerator RF systems; accelerator cavities; directional couplers; electron accelerators; APS linear accelerator; Advanced Photon Source; RF specification; WR 284 waveguide directional couplers; bolted-in vacuum windows; design; high power ultra-high vacuum dual-directional coupler; testing; vacuum windows; waveguide system; Directional couplers; Flanges; Frequency; Klystrons; Linear particle accelerator; Prototypes; Space vector pulse width modulation; Testing; Vacuum systems; Waveguide components;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 1995., Proceedings of the 1995
Conference_Location :
Dallas, TX
Print_ISBN :
0-7803-2934-1
Type :
conf
DOI :
10.1109/PAC.1995.505438
Filename :
505438
Link To Document :
بازگشت