DocumentCode :
1886876
Title :
Optimal design of corneal refractive surgery
Author :
Bryant, Michael R. ; Velinsky, Steven A.
Author_Institution :
Dept. of Mech. Eng., Wisconsin Univ., Madison, WI, USA
fYear :
1989
fDate :
9-12 Nov 1989
Firstpage :
1946
Abstract :
A methodology is described for the design of radial keratotomy procedures with elliptical optic zones. By coupling a transversely isotropic finite-element model of the cornea to an optical model of the eye and applying optimization techniques, an approach is developed that allows the correction of a patient´s myopia and astigmatism. An example, based on measured corneal geometry, illustrates the method for an eight-incision procedure
Keywords :
eye; optimisation; surgery; 8-incision procedure; astigmatism; corneal geometry; corneal refractive surgery; elliptical optic zones; eye optical model; myopia; optimal design; optimization techniques; radial keratotomy procedures; transversely isotropic finite-element model; Biomedical optical imaging; Cornea; Deformable models; Finite element methods; Geometry; Optical design; Optical refraction; Solid modeling; Surgery; Vision defects;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 1989. Images of the Twenty-First Century., Proceedings of the Annual International Conference of the IEEE Engineering in
Conference_Location :
Seattle, WA
Type :
conf
DOI :
10.1109/IEMBS.1989.96538
Filename :
96538
Link To Document :
بازگشت