DocumentCode
1886876
Title
Optimal design of corneal refractive surgery
Author
Bryant, Michael R. ; Velinsky, Steven A.
Author_Institution
Dept. of Mech. Eng., Wisconsin Univ., Madison, WI, USA
fYear
1989
fDate
9-12 Nov 1989
Firstpage
1946
Abstract
A methodology is described for the design of radial keratotomy procedures with elliptical optic zones. By coupling a transversely isotropic finite-element model of the cornea to an optical model of the eye and applying optimization techniques, an approach is developed that allows the correction of a patient´s myopia and astigmatism. An example, based on measured corneal geometry, illustrates the method for an eight-incision procedure
Keywords
eye; optimisation; surgery; 8-incision procedure; astigmatism; corneal geometry; corneal refractive surgery; elliptical optic zones; eye optical model; myopia; optimal design; optimization techniques; radial keratotomy procedures; transversely isotropic finite-element model; Biomedical optical imaging; Cornea; Deformable models; Finite element methods; Geometry; Optical design; Optical refraction; Solid modeling; Surgery; Vision defects;