Title :
Short-circuit fault mitigation methods for interior PM synchronous machine drives using six-leg inverters
Author :
Welchko, Brian A. ; Jahns, Thomas M. ; Lipo, Thomas A.
Author_Institution :
General Motors Adv. Technol. Center, Torrance, CA, USA
Abstract :
This paper characterizes six-leg inverters to mitigate short-circuit faults for interior permanent magnet (IPM) synchronous machines. Key differences between bus structures in six-leg inverters are identified. For six-leg inverters employing two isolated DC links, it is shown that up to 75% of rated output power could be produced following a single-switch short-circuit fault. A magnet flux ing control method is proposed as a response to stator winding type short-circuit faults. This control method results in a zero-torque fault response by the motor. The important influence of the zero sequence in both the motor and inverter structure is identified and developed for this class of fault. Simulation and experimental results are presented verifying the proposed magnet flux ing control method.
Keywords :
fault diagnosis; invertors; machine control; machine testing; magnetic flux; permanent magnet motors; short-circuit currents; stators; synchronous motor drives; torque; interior PM synchronous machine drives; isolated DC links; magnet flux ing control method; short-circuit fault mitigation methods; six-leg inverters; stator winding; zero-torque fault response; Circuit faults; Inverters; Magnetic flux; Permanent magnet motors; Permanent magnets; Reluctance motors; Switches; Synchronous machines; Synchronous motors; Torque;
Conference_Titel :
Power Electronics Specialists Conference, 2004. PESC 04. 2004 IEEE 35th Annual
Print_ISBN :
0-7803-8399-0
DOI :
10.1109/PESC.2004.1355448