Title :
Novel load adaptive frequency tracking control scheme for high frequency inverter without PLL scheme
Author :
Kifune, Hiroyasu ; Yamaguchi, Takumi ; Yoshida, Daichi ; Hatanaka, Yoshihiro ; Nakaoka, Mutsuo
Author_Institution :
Tokyo Univ. of Marine Sci. & Technol., Japan
Abstract :
A Load adaptive frequency tracking control scheme that is named conduction time balanced loop (CTBL) for the high frequency inverter is presented without PLL scheme. Using this control method for the gate circuit of the high frequency inverter that operates in resonant frequency, it is realized to have both the power regulation function and the load adaptive tracking control function by one inverter, though the conventional PLL high frequency inverter cannot do. This paper describes the principle of the proposed control scheme with high frequency inverter operation and the relation between the CTBL and the power regulation by the phase shift modulation.
Keywords :
adaptive control; frequency control; frequency convertors; phase locked loops; phase modulation; power control; resonant invertors; PLL scheme; conduction time balanced loop; frequency tracking control; gate circuit control; high frequency inverter; load adaptive control; phase shift modulation; power regulation function; resonant frequency; Adaptive control; Control systems; Phase locked loops; Phase modulation; Power generation; Programmable control; Pulse width modulation inverters; Resonant frequency; Resonant inverters; Tracking loops;
Conference_Titel :
Power Electronics Specialists Conference, 2004. PESC 04. 2004 IEEE 35th Annual
Print_ISBN :
0-7803-8399-0
DOI :
10.1109/PESC.2004.1355501