Abstract
The radiation shielding in the Fermilab Main Injector (FMI) complex has been carried out by adopting a number of prescribed stringent guidelines established by a previous safety analysis. Determination of the required amount of radiation shielding at various locations of the FMI has been done using Monte Carlo computations. A three dimensional ray tracing code as well as a code based upon empirical observations have been employed in certain cases
Keywords
Monte Carlo methods; particle beam injection; proton accelerators; ray tracing; shielding; synchrotrons; 3D ray tracing code; Fermilab Main Injector; Monte Carlo computations; empirical observations; radiation shielding; safety analysis; stringent guidelines; Colliding beam accelerators; Concrete; Guidelines; Monte Carlo methods; Particle beams; Protection; Proton accelerators; Radiation safety; Soil; US Department of Energy;