DocumentCode :
1892933
Title :
Safeguards for burning waste-derived fuel in cement kilns
Author :
Winingham, Wade
Author_Institution :
Ash Grove Cement Co., Louisville, NE, USA
fYear :
1993
fDate :
23-27 May 1993
Firstpage :
183
Lastpage :
200
Abstract :
The author responds to the charge that the cement industry is insufficiently regulated when using waste-derived fuel to fire cement kilns. The operating limits for Ash Grove´s no.2 kiln at its Louisville, Nebraska, facility are outlined, along with descriptions of the instrumentation required to monitor them. The conclusion is drawn that the numerous safeguards required when burning waste-derived fuel indicate that the cement industry is adequately regulated
Keywords :
air pollution detection and control; cement industry; combustion; fuel; safety; waste disposal; air pollution; cement kilns; combustion; instrumentation; monitoring; regulations; safety; waste disposal; waste-derived fuel; Ash; Cement industry; Fires; Fuels; Instruments; Kilns; Monitoring;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Cement Industry Technical Conference, 1993. Record of Conference Papers., 35th IEEE
Conference_Location :
Toronto, Ont.
ISSN :
1079-9931
Print_ISBN :
0-7803-0960-X
Type :
conf
DOI :
10.1109/CITCON.1993.296985
Filename :
296985
Link To Document :
بازگشت