• DocumentCode
    1893803
  • Title

    ANFIS based HVDC control and fault identification of HVDC converter

  • Author

    Santhosh, S.

  • Author_Institution
    Dept. of Electr. & Electron. Eng., Pannai Coll. of Eng. & Technol., Sivagangai, India
  • fYear
    2012
  • fDate
    13-15 Dec. 2012
  • Firstpage
    186
  • Lastpage
    190
  • Abstract
    Identifying errors in HVDC converter and controlling HVDC system is presented in my paper. The easy and exact connoisseur system is neatly presented applying ANFIS (Acclimatized Neuro-Fuzzy Inference system. In both inversion and rectification mode faults are being identified when high voltage direct current with strong ac side and high voltage direct current with weak ac sides are available and incorporated fault identifier is developed replacing the old system of using individual error identifier in complete bridge converter. The conventionally used controller is PI which are in the existing HVDC systems is clearly operating good, they are prone to changes in system limits, holdups or other non-linearities in the system and endure from some limitations. ANFLBI and ANFLBC are the fuzzy logic supported error identifier and current controller respectively. ANFIS controller can function independently with arithmetical replica of the system and controlled input under interruption condition can be obtained without difficulty. My proposed system is easily combinable with error identifier, which can perk up active response of HVDC system. Quite a lot of digital replication results are obtainable to authenticate the process sketched in the paper.
  • Keywords
    HVDC power convertors; PI control; control nonlinearities; electric current control; fault location; fuzzy control; fuzzy reasoning; neural nets; ANFIS-based HVDC control; ANFLBC; ANFLBI; HVDC converter; PI controller; acclimatized neuro-fuzzy inference system; arithmetical replica; connoisseur system; current controller; digital replication; error identification; fault identification; fuzzy logic; high voltage direct current; interruption condition; strong ac side; system holdups; system limits; system nonlinearities; weak ac side; ANFIS; ANFLBC; ANFLBI; HVDC converter; arithmetical replica; controller; error identifier;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Emerging Trends in Electrical Engineering and Energy Management (ICETEEEM), 2012 International Conference on
  • Conference_Location
    Chennai
  • Print_ISBN
    978-1-4673-4633-7
  • Type

    conf

  • DOI
    10.1109/ICETEEEM.2012.6494469
  • Filename
    6494469