DocumentCode
1895277
Title
Production line evaluation of geared DC motor mechanical efficiency
Author
Savage, Jack ; Suriano, John ; Micheli, Paul
fYear
2001
fDate
2001
Firstpage
387
Lastpage
392
Abstract
Mechanical and electrical characteristics of DC motors are important indicators of proper assembly and design integrity. Tests of the individual components of the motor can yield information on these parameters but this is not suitable for end of line testing after the motor is assembled. For geared motors it is desirable to evaluate the mechanical efficiency of the gearing and the amount of frictional loss in the motor as well as the electrical resistance and motor torque constant. This can be done using tests at three load points as described in this paper
Keywords
DC motors; assembling; electric resistance; friction; losses; machine theory; permanent magnet motors; production; torque; assembly; computer diagnostics; design integrity; electrical resistance; end of line testing; equivalent circuit; frictional loss; geared DC motor mechanical efficiency; geared motors; individual motor components testing; motor torque constant; permanent magnet DC motors; production line evaluation; Assembly; DC motors; Friction; Gears; Hysteresis motors; Permanent magnet motors; Production; Testing; Torque; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation Conference and Electrical Manufacturing & Coil Winding Conference, 2001. Proceedings
Conference_Location
Cincinnati, OH
ISSN
0362-2479
Print_ISBN
0-7803-7180-1
Type
conf
DOI
10.1109/EEIC.2001.965695
Filename
965695
Link To Document