Title :
An experimental setup for validating a CFD model of a double-sided PCB in a sealed enclosure at various power configurations
Author :
Johansson, Jonas ; Belov, Ilja ; Leisner, Peter
Author_Institution :
SaabTech AB, Jonkoping, Sweden
Abstract :
A flexible experimental setup enabling power control of a fully populated double-sided PCB has been realized, and is described in detail. A CFD model of a double-sided PCB housed in a sealed enclosure has been validated in a 19°C environment by means of temperature and flow measurement. The difference between simulated and measured component temperatures has been within 10%. Potential errors both in the model and in the experiments have been discussed and their impact on temperatures has been numerically evaluated.
Keywords :
computational fluid dynamics; finite volume methods; power electronics; printed circuit testing; printed circuits; reliability; thermal management (packaging); 19 C; CFD simulations; COTS components; double-sided PCB; flow measurement; power configurations; power control; power dissipation; sealed enclosure; temperature measurement; Aerospace electronics; Computational fluid dynamics; Computational modeling; Computer simulation; Cooling; Fluid flow measurement; Plastics; Power engineering and energy; Temperature measurement; Thermal management;
Conference_Titel :
Thermal, Mechanical and Multi-Physics Simulation and Experiments in Micro-Electronics and Micro-Systems, 2005. EuroSimE 2005. Proceedings of the 6th International Conference on
Print_ISBN :
0-7803-9062-8
DOI :
10.1109/ESIME.2005.1502787