DocumentCode :
1895696
Title :
Investigation of an improved flux estimator of a direct torque controlled interior permanent magnet synchronous machine drive
Author :
Tang, Linlin
Author_Institution :
New South Wales Univ., Sydney, NSW, Australia
Volume :
1
fYear :
2004
fDate :
20-25 June 2004
Firstpage :
451
Abstract :
In order to achieve good steady-state and dynamic performance, the flux estimation should be very accurate for a direct torque controlled (DTC) drive at all time. The effects of the stator resistance variation of the stator resistance and the forward voltage drops of the power switches are analyzed and compensated in this paper. Modeling and experimental results confirm the effectiveness of the proposed flux estimator.
Keywords :
invertors; machine vector control; permanent magnet motors; stators; switching convertors; synchronous motor drives; torque control; DTC; direct torque controlled drive; dynamic performance; flux estimation; forward voltage drop; power switches; stator resistance variation; steady-state performance; Australia; Couplings; Electric resistance; Induction machines; Inverters; Permanent magnet machines; Stators; Steady-state; Torque control; Voltage;