• DocumentCode
    1896313
  • Title

    Ion-chamber beam-loss-monitor system for the Los Alamos Meson Physics Facility

  • Author

    Plum, M. ; Brown, D. ; Browman, A. ; Macek, R.

  • Author_Institution
    Accel. Technol. Div., Los Alamos Nat. Lab., NM, USA
  • Volume
    4
  • fYear
    1995
  • fDate
    1-5 May 1995
  • Firstpage
    2554
  • Abstract
    A new loss monitor system has been designed and installed at the Los Alamos Meson Physics Facility (LAMPF). The detectors are ion chambers filled with N2 gas. The electronics modules have a threshold range of 1:100, and they can resolve changes in beam loss of about 2% of the threshold settings. They can generate a trip signal in 2 μs if the beam loss is large enough, and if we include the response time of the Fast Protect System, the beam will be shut off in about 37 μs
  • Keywords
    detector circuits; ionisation chambers; nuclear electronics; particle beam diagnostics; proton accelerators; storage rings; 2 mus; 37 mus; Fast Protect System; LAMPF; Los Alamos Meson Physics Facility; beam-loss-monitor system; electronics modules; ion chambers; proton storage ring; response time; trip signal; Detectors; Ion accelerators; Laboratories; Mesons; Monitoring; Nitrogen; Physics; Power supplies; Protection; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1995., Proceedings of the 1995
  • Conference_Location
    Dallas, TX
  • Print_ISBN
    0-7803-2934-1
  • Type

    conf

  • DOI
    10.1109/PAC.1995.505615
  • Filename
    505615