• DocumentCode
    1896412
  • Title

    Testing coaxial switches of BPM using a high-resolution RF detector

  • Author

    Ieiri, Takao

  • Author_Institution
    Nat. Lab. for High Energy Phys., Ibaraki, Japan
  • Volume
    4
  • fYear
    1995
  • fDate
    1-5 May 1995
  • Firstpage
    2566
  • Abstract
    A high-resolution RF detector has been developed in order to test a coaxial switch used in a beam-position monitor (BPM). The detector with a digital multi-meter (DMM) has an RMS resolution of the order of 10-6 in short time and a wide linear range of 50 dB. Though detected voltage depends on temperature, it can be compensated by measuring the detector temperature. The insertion loss and its stability of several types of switches were measured at 1.0 GHz using the detector. The normalized positions are kept within ±3x10-5, which corresponds to about ±1.0 μm in a chamber of the KEKB. The detector is useful to evaluate the insertion loss of switches
  • Keywords
    accelerator RF systems; digital multimeters; electron accelerators; particle beam diagnostics; position measurement; semiconductor switches; storage rings; 1 GHz; KEKB; RMS resolution; beam-position monitor; coaxial switches testing; digital multimeter; high-resolution RF detector; insertion loss; normalized positions; switches stability; Coaxial components; Detectors; Insertion loss; Monitoring; Radio frequency; Switches; Temperature dependence; Temperature measurement; Testing; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1995., Proceedings of the 1995
  • Conference_Location
    Dallas, TX
  • Print_ISBN
    0-7803-2934-1
  • Type

    conf

  • DOI
    10.1109/PAC.1995.505619
  • Filename
    505619