• DocumentCode
    1898542
  • Title

    Remote effects of electromagnetic millimeter waves on experimentally induced cold pain — A crossover double-blinded investigation in healthy volunteers

  • Author

    Partyla, Thomasz ; Leutzow, Bianca ; Edinger, Hardy ; Wendt, Michael ; Usichenko, Taras

  • Author_Institution
    Dept. of Anesthesiology, Univ. Med. of Greifswald, Greifswald, Germany
  • fYear
    2012
  • fDate
    10-14 Sept. 2012
  • Firstpage
    977
  • Lastpage
    978
  • Abstract
    The hypoalgesic effect of millimeter waves (MW) was studied using experimental pain model of Cold Pressor Test (CPT) in healthy volunteers. Skin of the lower part of sternum of each volunteer was exposed to either source of MW with 42.25 GHz ("fixed frequency" generator), 50-75 GHz ("noise frequency" generator) or inactive device ("placebo" generator) in a random order. Pain threshold, pain tolerance and diastolic blood pressure within CPT increased under the exposure to "frequency generator" as compared to baseline and to "noise" generator, but not vs. placebo.
  • Keywords
    biomedical equipment; cellular effects of radiation; diseases; electromagnetic waves; millimetre waves; noise generators; radiation therapy; skin; cold pressor testing; crossover double-blinded investigation; diastolic blood pressure; electromagnetic millimeter waves; experimental pain model; experimentally induced cold pain; frequency 42.25 GHz; frequency 50 GHz to 75 GHz; frequency generator; healthy volunteers; hypoalgesic effect; noise generator; pain threshold; placebo generator; remote effects; skin; sternum; Blood pressure; Generators; Noise; Pain; Pressure measurement; Skin; Temperature measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave and Telecommunication Technology (CriMiCo), 2012 22nd International Crimean Conference
  • Conference_Location
    Sevastopol, Crimea
  • Print_ISBN
    978-1-4673-1199-1
  • Type

    conf

  • Filename