Title :
Validation of the transformer magnetic circuit model
Author :
Espinoza, José Roberto ; Pérez-Rojas, C. ; García-Martínez, S.
Author_Institution :
Electr. Eng. Fac., UMSNH, Morelia, Mexico
Abstract :
Model validation is an important stage in the investigation process, because it permits to ensure the efficiency of the developed models. Commonly, implemented model uses geometric transformer data instead of manufacturer data and they approximate transformer characteristics to make the simulation process simpler. Measurements on actual laboratory transformer are presented for validation of the transformer´s magnetic method. We considered only the saturation effect using the arctangent function.
Keywords :
magnetic circuits; power transformers; arctangent function; geometric transformer data; saturation effect; transformer characteristics; transformer magnetic circuit model; transformer magnetic method; Circuit faults; Current measurement; Integrated circuit modeling; Magnetic circuits; Transformer cores; Windings; Validation; arctangent function for saturation; transformer magnetic model;
Conference_Titel :
North American Power Symposium (NAPS), 2012
Conference_Location :
Champaign, IL
Print_ISBN :
978-1-4673-2306-2
Electronic_ISBN :
978-1-4673-2307-9
DOI :
10.1109/NAPS.2012.6336432