DocumentCode :
1905424
Title :
Developments of optical frequency standards at NICT and all-optical comparison against a remote clock in University of Tokyo using 60km fiber link
Author :
Koyama, Yasuhiro ; Fujieda, Miho ; Hachisu, Hidekazu ; Ido, Tetsuya ; Kojima, Reiko ; Kumagai, Motohiro ; Li, Ying ; Matsubara, Kensuke ; Nagano, Shigeo ; Shiga, Nobuyasu ; Yamaguchi, Atsushi
Author_Institution :
Nat. Inst. of Inf. & Commun. Technol., Tokyo, Japan
fYear :
2011
fDate :
13-20 Aug. 2011
Firstpage :
1
Lastpage :
4
Abstract :
At National Institute of Information and Communications Technology (NICT), we have lately developed a lattice clock using 87Sr atoms as well as a single ion clock based on 40Ca+. Besides the comparison of the two atomic standards inside the institute, all-optical fiber-link to transfer frequency standards to the University of Tokyo (UT) has been developed to evaluate the uncertainty and stability of our standards by referring the state-of-the-art lattice clock locating in UT. The initial evaluations have resulted in the relative stability of 10-16 level, clearly showing the differential frequency of 4-5Hz mainly caused by the 45m difference of the elevation.
Keywords :
atomic clocks; calcium; frequency standards; strontium; all-optical comparison; all-optical fiber-link; differential frequency; distance 60 km; frequency 4 Hz to 5 Hz; lattice clock; optical frequency standards; relative stability; remote clock; Clocks; Frequency measurement; Lattices; Optical fiber communication; Optical fibers; Standards;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
General Assembly and Scientific Symposium, 2011 XXXth URSI
Conference_Location :
Istanbul
Print_ISBN :
978-1-4244-5117-3
Type :
conf
DOI :
10.1109/URSIGASS.2011.6050326
Filename :
6050326
Link To Document :
بازگشت