Title :
Time domain calibration of pulsed current probe
Author :
Shi, Lihua ; Tan, Jianwen ; Zhou, Bihua
Author_Institution :
Lab. of Electromgnetics, Nanjing Eng. Inst.
fDate :
Feb. 27 2006-March 3 2006
Abstract :
For the measurement of nanosecond pulsed current, time domain calibration of current probes is discussed. A dynamic model for a self-integrating Rogowski coil is established based on the time domain calibration data. This modeling method can be used to describe the low-frequency distortion of the probe and it can also be used to compensate the distorted output of the probe. The validity of the established model is verified by experimental data both in time domain and in frequency domain
Keywords :
calibration; coils; electric current measurement; time-frequency analysis; Rogowski coil; frequency domain; low-frequency distortion; nanosecond pulsed current; pulsed current probe; time domain calibration; Calibration; Coils; Current measurement; Distortion measurement; Frequency domain analysis; Probes; Pulse measurements; Time domain analysis; Time measurement; Voltage;
Conference_Titel :
Electromagnetic Compatibility, 2006. EMC-Zurich 2006. 17th International Zurich Symposium on
Conference_Location :
Singapore
Print_ISBN :
3-9522990-3-0
DOI :