• DocumentCode
    1908359
  • Title

    Leak detection of gas transport pipelines based on wigner distribution

  • Author

    Yang, Hongying ; Ye, Hao ; Zhai, Shouchao ; Wang, Guizeng

  • Author_Institution
    Comput. Sci. & Technol. Dept., Tsinghua Univ., Beijing, China
  • fYear
    2011
  • fDate
    23-26 May 2011
  • Firstpage
    258
  • Lastpage
    261
  • Abstract
    This paper reports on the application of Wigner-Ville Distribution (WVD) method in leak detection of gas transport pipelines. WVD of the acoustic signal inside a pipeline is used to detect the change of the signal caused by leak. In order to reduce the influence of cross term disturbances, the time average of WVD results is calculated and used as the residual to detect leak faults. Experimental results based on real data show that the method can detect the leak faults of long gas transport pipelines effectively.
  • Keywords
    Wigner distribution; acoustic signal processing; condition monitoring; fault diagnosis; leak detection; pipelines; Wigner-Ville Distribution method; acoustic signal; fault detection; gas transport pipelines; leak detection; Acoustics; Leak detection; Monitoring; Pipelines; Signal analysis; Time frequency analysis; Transforms;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Advanced Control of Industrial Processes (ADCONIP), 2011 International Symposium on
  • Conference_Location
    Hangzhou
  • Print_ISBN
    978-1-4244-7460-8
  • Electronic_ISBN
    978-988-17255-0-9
  • Type

    conf

  • Filename
    5930433