    Optimization of the Energy Resolution of the Diffusion Based Nuclear Radiation Sensors

  • Author

    Otaredian, T. ; Wouters, S.E.

  • Author_Institution
    Delft University of Technology, Department of Electrical Engineering, Electronic Instrumentation Laboratory, P.O. Box 5031, 2600 GA, Delft, The Netherlands.
  • fYear
    1991
  • fDate
    16-19 Sept. 1991
  • Firstpage
    297
  • Lastpage
    300
  • Abstract
    The diffusion based nuclear radiation sensors have the main advantage of compatibility with the standard IC processing. However, these sensors suffer from a poor energy resolution which is disproportional to its external efficiency. This paper shows that these sensors can be improved by optimizing the detector thickness for a particular application with respect to its energy resolution and external efficiency.
  • Keywords
    Detectors; Energy measurement; Energy resolution; Laboratories; Microelectronics; Nuclear electronics; Nuclear power generation; Optoelectronic and photonic sensors; Power engineering and energy; Voltage;