• DocumentCode
    1908806
  • Title

    On the mechanisms of differential-mode to common-mode conversion in the broadband over power line (BPL) frequency band

  • Author

    Vukicevic, Ana ; Rubinstein, Marcos ; Rachidi, Farhad ; Bermudez, José-Luis

  • Author_Institution
    EMC Group, Swiss Fed. Inst. of Technol., Lausanne
  • fYear
    2006
  • fDate
    Feb. 27 2006-March 3 2006
  • Firstpage
    658
  • Lastpage
    661
  • Abstract
    The conversion between the common and the differential modes is of great importance in the transmission of data over poorly balanced cables such as electrical wiring. In this paper, we have studied some of the mechanisms involved in this conversion, both experimentally and theoretically. The results show that along-the-line variations in the line parameters be it gradual or abrupt, are responsible for part of the common mode in electric cables. Asymmetries at the source are also responsible for part of the common mode conversion and they can be dominant in certain cases
  • Keywords
    broadband networks; carrier transmission on power lines; power cables; broadband; common-mode conversion; differential-mode; electric cables; line parameters; power line frequency band; Broadband communication; Cables; Circuits; Conducting materials; Delta modulation; Electromagnetic compatibility; Frequency conversion; Modems; Power line communications; Wiring;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 2006. EMC-Zurich 2006. 17th International Zurich Symposium on
  • Conference_Location
    Singapore
  • Print_ISBN
    3-9522990-3-0
  • Type

    conf

  • DOI
    10.1109/EMCZUR.2006.215020
  • Filename
    1629710