Data center cooling management and analysis - a model based approach
Author :
Zhou, Rongliang ; Wang, Zhikui ; Bash, Cullen E. ; McReynolds, Alan
Author_Institution :
Sustainable Ecosyst. Res. Group, Hewlett-Packard Co., Palo Alto, CA, USA
fYear :
2012
fDate :
18-22 March 2012
Firstpage :
98
Lastpage :
103
Abstract :
As the hub of information aggregation, processing, and dissemination, today´s data centers consume significant amount of energy. The data center electricity consumption mainly comes from the IT equipment and the supporting cooling facility that manages the thermal status of the IT equipment. The traditional data center cooling facility usually consists of chilled water cooled computer room air conditioning (CRAC) units and chillers that provide chilled water to the CRAC units. Electricity used to power the cooling facility could take up to a half of the total data center electricity consumption, and is a major contributor to the data center total cost of ownership. While the data center industry has established the best practice to improve the cooling efficiency, the majority of it is rule of thumbs providing only qualitative guidance. In order to provide on demand cooling and achieve improved cooling efficiency, a model based description of the data center thermal environment is indispensable. In this paper, a computationally efficient multivariable model capturing the effects of CRAC units blower speed and supply air temperature (SAT) on rack inlet temperatures is introduced, and model identification and reduction procedures are discussed. Using the model developed, data center cooling system design and analysis such as thermal zone mapping, CRAC units load balancing, and hot spot detection are investigated.
Keywords :
aggregation; air conditioning; computer centres; cooling; resource allocation; thermal management (packaging); CRAC units; IT equipment; air conditioning; blower speed; chilled water cooled computer room; cooling management; data center; electricity consumption; hot spot detection; information aggregation; information dissemination; information processing; load balancing; rack inlet temperatures; supply air temperature; thermal status; thermal zone mapping;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Semiconductor Thermal Measurement and Management Symposium (SEMI-THERM), 2012 28th Annual IEEE
Conference_Location :
San Jose, CA
ISSN :
1065-2221
Print_ISBN :
978-1-4673-1110-6
Electronic_ISBN :
1065-2221
Type :
conf
DOI :
10.1109/STHERM.2012.6188832
Filename :
6188832
Link To Document :
بازگشت