An harmonic test condition for the metrological characterization and the operating principle identification of reactive static meters
Author :
Cataliotti, Antonio ; Cosentino, Valentina ; Lipari, Alessandro ; Nuccio, Salvatore
Author_Institution :
Dept. of Electr., Univ. di Palermo, Palermo
fYear :
2008
fDate :
12-15 May 2008
Firstpage :
1269
Lastpage :
1273
Abstract :
This paper faces the problem of the metrological characterization of the static meters for reactive energy in the presence of harmonic distortion. Starting from the only available accuracy test condition in the presence of harmonics introduced in the Standards for active static meters, an experimental approach is proposed for the verification of such meters in the presence of harmonic distortion, as well as for the individuation of their operating principle. A theoretical validation of the obtained results is presented by means of a comparison with a standard and a commercial static meter with a known operating principle.
Keywords :
harmonic distortion; power measurement; power meters; power system harmonics; reactive power; testing; harmonic distortion; harmonic test condition; metrological characterization; reactive static meters; Distortion measurement; Energy measurement; Frequency; Harmonic distortion; Industrial power systems; Power system harmonics; Power system measurements; Testing; Voltage; Watthour meters; energy measurements; harmonic distortion; power quality; power systems;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Instrumentation and Measurement Technology Conference Proceedings, 2008. IMTC 2008. IEEE
Conference_Location :
Victoria, BC
ISSN :
1091-5281
Print_ISBN :
978-1-4244-1540-3
Electronic_ISBN :
1091-5281
Type :
conf
DOI :
10.1109/IMTC.2008.4547237
Filename :
4547237
Link To Document :
بازگشت