DocumentCode :
1914096
Title :
Optimal operation of cold end system for steam turbine in coal-fired power plant
Author :
Wang Yun-min ; Zhang Lun-zhu
Author_Institution :
Coll. of Energy & Power Eng., Changsha Univ. of Sci. & Technol., Changsha, China
Volume :
2
fYear :
2011
fDate :
20-22 May 2011
Firstpage :
1645
Lastpage :
1649
Abstract :
The optimal operation of cold end system of steam turbine is an important measure to saving energy in power plant. This article takes the cold end system of steam turbine in coal-fired power plant from actual conditions, in determining the optimized vacuum and optimized cooling water flow, many factors such as economy, thermal pollution cost and water fee of cooling water have been considered. So it is more fit to reality. In the course of study, taking the domestic 600MW unit as an example, the optimal operation of cold end system of steam turbine is analyzed and calculated.
Keywords :
combined cycle power stations; energy conservation; optimisation; steam turbines; coal fired power plant; cold end system; cooling water; energy saving; optimization; steam turbine; Cooling; Equations; Government; Heat pumps; Heating; coal-fired power plant; cold end system; optimal operation; steam turbine;