Title :
Use of heat pipe/heat sink for thermal management of high performance CPUs
Author :
Nguyen, Tliang ; Mochizuki, Masataka ; Mashiko, Koichi ; Saito, Yuji ; Sauciuc, Ioan
Author_Institution :
Fujikura Ltd., Tokyo, Japan
Abstract :
This paper will describe various cooling solutions in notebook PC and desktop/server applications. In the notebook PC application, miniature heat pipes of diameter 3-6 mm, flatten to desire thickness, are commonly used to improve heat spreading and more efficient transfer heat generated from the CPU to a remote heat dissipation area. Examples of three typical thermal solutions in notebook PC are given in this paper. Whereas in the desktop server application, flat type rectangular heat pipes or so-called vapor chambers are used to attach under the base of the heat sink to help temperature uniformity across the heat sink base. This will reduce the spreading resistance in the heat sink base and therefore improve the heat sink performance. Experimental results showed that with a vapor chamber installed can achieved a 45% improvement in the heat sink performance for heat sink of length 110 mm, width 72.5 mm, height 50 mm and base thickness 7 mm
Keywords :
cooling; heat exchangers; heat pipes; heat sinks; microcomputers; notebook computers; temperature distribution; thermal management (packaging); thermal resistance; cooling solutions; desktop server application; flat type rectangular heat pipes; heat sink; heat spreading; high performance CPUs; miniature heat pipes; notebook PC application; remote heat dissipation area; remote heat exchanger system; spreading resistance; temperature uniformity; thermal management; vapor chambers; Aluminum; Connectors; Heat sinks; Heat transfer; Keyboards; Resistance heating; Surface resistance; Temperature; Thermal management; Thermal resistance;
Conference_Titel :
Semiconductor Thermal Measurement and Management Symposium, 2000. Sixteenth Annual IEEE
Conference_Location :
San Jose, CA
Print_ISBN :
0-7803-5916-X
DOI :
10.1109/STHERM.2000.837064