DocumentCode :
1919624
Title :
A Case Study of an Electrolytic Tinning Line, with an Analysis of Faults in the Power Rectifiers
Author :
Díaz, Guzmáin ; Arboleya, Pablo ; De Abajo, Nicolás ; Reigosa, David
Author_Institution :
Dept. of Electr. Eng., Oviedo Univ., Gijon
Volume :
2
fYear :
2005
fDate :
21-24 Nov. 2005
Firstpage :
1247
Lastpage :
1250
Abstract :
A model is represented in this paper to simulate the tin plating coating process. The control of the output current provided by high current rectifiers (HCR) is the best way to assure the quality of the final product. The model includes the interaction of power rectifiers and thickness of the final coating. ARMAX model has been used for this purpose. An application of the model is presented to identify faults in the set of power rectifiers
Keywords :
autoregressive moving average processes; electrolytic rectifiers; electroplating; fault diagnosis; tin compounds; ARMAX model; electrolytic tinning line; fault analysis; power rectifiers; tin plating coating process; Coatings; Computer aided software engineering; Fault diagnosis; Leg; Power semiconductor devices; Production; Rectifiers; Semiconductor device reliability; Thyristors; Topology; SOM; artificial neural networks; models; power rectifiers;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Computer as a Tool, 2005. EUROCON 2005.The International Conference on
Conference_Location :
Belgrade
Print_ISBN :
1-4244-0049-X
Type :
conf
DOI :
10.1109/EURCON.2005.1630182
Filename :
1630182
Link To Document :
بازگشت