DocumentCode :
1924067
Title :
Practical iterative reconstruction methods for quantitative cardiac SPECT image reconstruction
Author :
Tsui, B.M.W. ; Zhao, X.D.
Author_Institution :
Dept. of Biomed. & Radiol., North Carolina Univ., Chapel Hill, NC, USA
fYear :
1992
fDate :
25-31 Oct 1992
Abstract :
Summary form only given. The authors investigate the practical implementation of iterative reconstruction methods to improve the quality and quantitative accuracy of cardiac single photon emission computed tomography (SPECT) images over the filtered backpropagation (FB) algorithm. A cardiac-chest phantom based on a patient CT scan and Tl-201 uptake data was used in the study. Projection data were generated which included the effects of nonuniform attenuation detector response, scatter and noise. Use was made of the iterative Chang algorithm with nonuniform attenuation compensation only, the iterative maximum likelihood-expectation maximization (ML-EM) and WLS-CG methods, and variations of the WLS-CG methods, including the use of the FB or Chang reconstructed image as initial estimate and filtering to suppress noise amplifications at high iteration number. The mean-square-error over the region of the heart and the normalized standard deviation over a background region were used to evaluate the different reconstruction methods. It was found that, using the Chang reconstructed image as the initial estimate in the WLS-CG method together with filtering between iterations, cardiac SPECT images with good quality and quantitative accuracy can be obtained in a few iterations
Keywords :
cardiology; computerised tomography; image reconstruction; medical image processing; Chang reconstructed image; cardiac-chest phantom; filtered backpropagation algorithm; filtering; iterative Chang algorithm; iterative maximum likelihood-expectation maximization; iterative reconstruction methods; mean-square-error; noise amplifications; nonuniform attenuation compensation; nonuniform attenuation detector response; patient CT scan; quantitative cardiac SPECT image reconstruction; scatter; single photon emission computed tomography images; Attenuation; Backpropagation algorithms; Computed tomography; Filtering; Image reconstruction; Imaging phantoms; Iterative algorithms; Iterative methods; Reconstruction algorithms; Single photon emission computed tomography;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference, 1992., Conference Record of the 1992 IEEE
Conference_Location :
Orlando, FL
Print_ISBN :
0-7803-0884-0
Type :
conf
DOI :
10.1109/NSSMIC.1992.301042
Filename :
301042