• DocumentCode
    1925703
  • Title

    A prototype RICH detector

  • Author

    Maia, M. Pommot ; Cooper, P.S. ; Stutte, L. ; Solyanik, V. ; Filimonov, I. ; Nemitkin, A.

  • Author_Institution
    Conselho Nacional de Pesquisas, Brazil
  • fYear
    1992
  • fDate
    25-31 Oct 1992
  • Firstpage
    156
  • Abstract
    A prototype RICH detector with a phototube-based photocathode array has been successfully tested, utilizing three different phototubes in the array. For 400 GeV/c π-, 11.8 photons per ring were detected and the ring radius resolution obtained was 1.13%. This is sufficient to provide useful separation of pions and kaons up to 250 GeV/c. The figure of merit for the entire photocathode was measured to be 93/cm
  • Keywords
    Cherenkov counters; meson detection and measurement; photocathodes; figure of merit; photocathode; pion kaon separation; prototype RICH detector; Cables; Cathodes; Connectors; Detectors; Fires; Glass; Mirrors; Noise level; Photoelectricity; Prototypes;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference, 1992., Conference Record of the 1992 IEEE
  • Conference_Location
    Orlando, FL
  • Print_ISBN
    0-7803-0884-0
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1992.301119
  • Filename
    301119