DocumentCode
1926369
Title
Precision calorimetry for power loss measurement of a very low power maximum power point tracker
Author
Wolfs, Peter ; Li, Quan
Author_Institution
Central Queensland Univ., Rockhampton, QLD
fYear
2007
fDate
9-12 Dec. 2007
Firstpage
1
Lastpage
5
Abstract
Efficiency is an important performance measure for DC-DC converters. Its measurement can be extremely difficult when the DC-DC converter is highly efficient and the power loss is extremely low. The input and the output waveforms of a high frequency dc-dc converter may have high frequency components superimposed on the DC components. This further complicates the measurement process as some digital instruments tend to misbehave. Calorimetry method has been previously proposed as an alternative and indirect power loss measurement method. This paper proposes an improved calorimetry method which is capable of resolving the power loss below 2 mW. The method is demonstrated for a single-cell maximum power point tracker with a power rating of 650 mW. The experimental results confirm that the device under test presents a power loss of 24 mW +1.3 mW and the converter achieves an efficiency of 96.2% + 0.2%.
Keywords
DC-DC power convertors; calorimetry; loss measurement; losses; DC-DC converters; calorimetry method; efficiency -0.2 percent; efficiency 0.2 percent; efficiency 96.2 percent; low power maximum power point tracker; power -1.3 mW; power 1.3 mW; power 24 mW; power 650 mW; power loss; power loss measurement; Calorimetry; DC-DC power converters; Frequency conversion; Frequency measurement; Instruments; Loss measurement; Power conversion; Power measurement; Target tracking; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Engineering Conference, 2007. AUPEC 2007. Australasian Universities
Conference_Location
Perth, WA
Print_ISBN
978-0-646-49488-3
Electronic_ISBN
978-0-646-49499-1
Type
conf
DOI
10.1109/AUPEC.2007.4548042
Filename
4548042
Link To Document