DocumentCode
1926995
Title
Impedance transformers for compact and robust coupled magnetic resonance systems
Author
Eunsoo Lee ; Jin Huh ; XuanVan Thai ; Suyong Choi ; Chuntaek Rim
Author_Institution
Dept. of Nucl. & Quantum Eng., KAIST, Daejeon, South Korea
fYear
2013
fDate
15-19 Sept. 2013
Firstpage
2239
Lastpage
2244
Abstract
An innovative coupled magnetic resonance system (CMRS), introducing two lumped impedance transformers, is proposed. The source coil and load coil of conventional CMRS are replaced with two cored transformers so that the system can be quite compact in size and robust to ambient changes. The design of the system is simplified due to no magnetic flux leakage from the source coil and load coil. A class-E inverter at 500 kHz switching frequency was used for experiments. It is concluded in this paper that the CMRS, in general, is a special form of conventional inductive power transfer systems.
Keywords
coils; impedance convertors; invertors; magnetic resonance; CMRS; class-E inverter; frequency 50 kHz; inductive power transfer systems; innovative coupled magnetic resonance system; load coil; lumped impedance transformers; source coil; switching frequency; Coils; Impedance; Inductance; Inverters; Magnetic cores; Magnetic resonance; Wireless communication;
fLanguage
English
Publisher
ieee
Conference_Titel
Energy Conversion Congress and Exposition (ECCE), 2013 IEEE
Conference_Location
Denver, CO
Type
conf
DOI
10.1109/ECCE.2013.6646985
Filename
6646985
Link To Document