• DocumentCode
    1935175
  • Title

    How reliable is a RAID?

  • Author

    Schulze, Martin ; Gibson, Garth ; Katz, Randy ; Patterson, David

  • Author_Institution
    Dept. of Electr. Eng. & Comput. Sci., California Univ., Berkeley, CA, USA
  • fYear
    1989
  • fDate
    Feb. 27 1989-March 3 1989
  • Firstpage
    118
  • Lastpage
    123
  • Abstract
    Disk arrays offer greatly increased transfer bandwidth at low cost, but without additional data redundancy they can suffer from significantly degraded reliability. The authors examine the reliability of RAID (redundant arrays of inexpensive disks) systems and find that although extremely reliable disk arrays cannot be attained with data redundancy alone, RAID system reliability can be made better than conventional large disks with little extra hardware. They show that the rest of the system components, such as the host bus adapters, power supplies, and fans cannot be ignored. The authors present a scheme in which the system support components are organized into groups orthogonal to the data redundancy groups, thus guaranteeing that no single disk or component failure will permanently lose data. This approach yields disk arrays with reliability about 50% greater than conventional disk subsystems. If further reliability improvements are sought, various parts of the support hardware can be made redundant. The authors have shown how these affect the design of a 49-data-disk RAID.<>
  • Keywords
    magnetic disc storage; 49-data-disk; data redundancy; disk arrays; redundant arrays of inexpensive disks; reliability; support hardware; transfer bandwidth; Availability; Bandwidth; Cities and towns; Computer science; Costs; Drives; Equations; Hardware; Power system reliability; Redundancy;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    COMPCON Spring '89. Thirty-Fourth IEEE Computer Society International Conference: Intellectual Leverage, Digest of Papers.
  • Conference_Location
    San Francisco, CA, USA
  • Print_ISBN
    0-8186-1909-0
  • Type

    conf

  • DOI
    10.1109/CMPCON.1989.301913
  • Filename
    301913