DocumentCode :
1935659
Title :
The impact of capacitive voltage, due to concentric cable, on Signalling circuits
Author :
Beirne, Philip ; Mulready, Kieran ; Ogunsola, Ade
fYear :
2009
fDate :
12-12 Feb. 2009
Firstpage :
1
Lastpage :
5
Abstract :
Railway signalling line circuits are critical to the safe operation of the railway. This paper discusses the electromagnetic compatibility aspects of these circuits at the fundamental operating frequency. At low frequencies, we are [generally] only concerned with the voltage and current rating of the conductors and ensuring that the volt drop at rated current remains within acceptable values. In the case of high frequency signals attenuation and propagation delay become more significant and a transmission line approach is necessary. Here we consider the middle ground; long AC line circuits where the effect of cable capacitance needs to be carefully considered in order to prevent malfunction of safety critical circuits and may be affected by difference in cable geometries, selected for other equally worthy reasons.
Keywords :
capacitance; coaxial cables; railway safety; signalling; transmission line theory; cable capacitance; capacitive voltage; concentric cable; electromagnetic compatibility; high frequency signals attenuation; long AC line circuits; malfunction prevention; propagation delay; railway signalling line circuits; safe operation; safety critical circuits; transmission line approach; Signalling cables; capacitive coupling;
fLanguage :
English
Publisher :
iet
Conference_Titel :
EMC in Railways, 2009 IET Seminar on
Conference_Location :
London
ISSN :
0537-9989
Print_ISBN :
978-1-84919-059-6
Type :
conf
Filename :
5067543
Link To Document :
بازگشت