DocumentCode :
1935975
Title :
Enhancing time-frequency parameters estimation for Doppler Ultrasound blood-flow signals
Author :
Zabihian, Behrooz ; Ruano, M. Graça
Author_Institution :
Fac. of Sci. & Technol., Univ. do Algarve, Faro, Portugal
fYear :
2011
fDate :
19-21 Sept. 2011
Firstpage :
1
Lastpage :
5
Abstract :
Doppler Ultrasound (DU) blood flow signals, particularly when collected under intra-operative conditions are noisy; accurate extraction of clinical parameters from their spectra becomes a difficult task. The spectral center frequency and bandwidth were estimated using two estimators with alternative time-frequency resolutions: a fixed resolution method, the Short-Time Fourier Transform (STFT) and the multi-resolution Continuous Wavelet Transform (CWT). Their performance was also assessed when the DU signals were pre-processed by a recently proposed Noise Cancellation Technique (NCTech). The NCTech algorithm enables quantification of the magnitude of the canceled noise in the form of percentage, called Cancellation Level (CL). Quantitative comparisons have been performed in terms of bias of the estimators when four signal-to-noise (SNRs) on DU simulated signals are employed: infinity, 20 dB, 10 dB and 5 dB. Results prove that CWT produced spectral parameters estimates with less bias than STFT; however these estimates were less consistent than the STFT ones. When NCTech is primarily applied to the signal, the STFT is the method to benefit most from this pre-processing technique. The CWT combined with NCTech produced estimates of both spectral parameters with better accuracy over the majority of the cardiac cycle, except where the frequency varies within a small range of frequencies during a short period of time.
Keywords :
Doppler effect; Fourier transforms; biomedical ultrasonics; cardiology; frequency estimation; haemodynamics; medical signal processing; signal denoising; signal resolution; time-frequency analysis; wavelet transforms; NCTech algorithm; SNR; STFT; bandwidth estimation; cancellation level; cardiac cycle; clinical parameter extraction; doppler ultrasound blood-flow signal; fixed resolution method; intraoperative condition; multiresolution CWT; multiresolution continuous wavelet transform; noise cancellation technique; pre-processing technique; short-time Fourier transform; signal-to-noise ratio; spectral center frequency estimation; time-frequency parameter estimation; time-frequency resolution; Bandwidth; Blood; Continuous wavelet transforms; Estimation; Frequency estimation; Noise; Time frequency analysis;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Intelligent Signal Processing (WISP), 2011 IEEE 7th International Symposium on
Conference_Location :
Floriana
Print_ISBN :
978-1-4577-1403-0
Type :
conf
DOI :
10.1109/WISP.2011.6051708
Filename :
6051708
Link To Document :
بازگشت