DocumentCode
1936201
Title
Inverting faults in a three phase line commutated DC drive
Author
Schieman, R.G.
Author_Institution
Reliance Electr. Co., Athens, GA, USA
fYear
1989
fDate
1-5 Oct. 1989
Firstpage
943
Abstract
The various factors that result in an insufficient thyristor turn-off time and a resulting inverter failure are discussed. A recommended maximum converter voltage for typical industrial conditions is also presented. Data from a laboratory test setup are tabulated to confirm the results.<>
Keywords
DC motors; commutation; electric drives; electrical faults; invertors; thyristor applications; inverter failure; power convertors; three phase line commutated DC drive; thyristor turn-off time; voltage; AC motors; Armature; Circuit faults; Commutation; Inductance; Induction motors; Machine windings; Servomotors; Thyristors; Voltage;
fLanguage
English
Publisher
ieee