DocumentCode
1938250
Title
Triangle impulse response (TIR) calculation for lossy transmission line simulation
Author
Zhou, Tingdong ; Chen, Zhaoqing ; Becker, Wiren D. ; Dvorak, Steven L. ; Prince, John L.
Author_Institution
Dept. of Electr. & Comput. Eng., Arizona Univ., Tucson, AZ, USA
fYear
2001
fDate
2001
Firstpage
251
Lastpage
254
Abstract
Triangle-Impulse-Responses (TIR) are accurately calculated using an inverse Laplace transform algorithm. Frequency dependent transmission line parameters, i.e., R, L, G, and C, are used due to the skin effect and the frequency dependent electrical properties of the substrate material. The calculated TIR can be further used to carry out time domain simulations for a large number of lossy transmission lines
Keywords
Laplace transforms; skin effect; time-domain analysis; transient response; transmission line theory; electrical properties; frequency dependent parameters; inverse Laplace transform algorithm; lossy transmission line; skin effect; substrate material; time domain simulation; triangle impulse response; Capacitance; Computational modeling; Computer simulation; Frequency dependence; Inductance; Laplace equations; Power transmission lines; Propagation losses; Skin effect; Transmission lines;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Performance of Electronic Packaging, 2001
Conference_Location
Cambridge, MA
Print_ISBN
0-7803-7024-4
Type
conf
DOI
10.1109/EPEP.2001.967657
Filename
967657
Link To Document