• DocumentCode
    1941917
  • Title

    Three detecting methods of transient power quality disturbances in DVR

  • Author

    Ren, Yongfeng ; Cao, Limin ; Xu, Shaohua ; Li, Jianlin ; Li, Hanshan

  • Author_Institution
    Coll. of Inf. Eng., Inner Mongolia Univ. of Technol., Hohhot, China
  • fYear
    2010
  • fDate
    13-15 Aug. 2010
  • Firstpage
    29
  • Lastpage
    33
  • Abstract
    Dynamic voltage restorer (DVR) is widely applied to industry because it can reduce the impact of voltage disturbance to sensitive loads. The three detecting methods to extracted distortion components of DVR based on Hilbert transform, wavelet transform, and the instantaneous reactive power theory produce are introduced in details, respectively. Comparisons of working performance among these difference detecting methods of DVR are applied to power quality disturbance analysis under various run conditions. The results show that the method of Hilbert transform doesn´t detect distortion voltage of containing harmonic; the method of instantaneous reactive power theory can detect harmonic components, but doesn´t detect distortion voltage of containing voltage sags; the method of wavelet transform has best detecting performance under different run conditions. Simulation results verify three detecting methods´ applicability and effectiveness in DVR system.
  • Keywords
    Hilbert transforms; power supply quality; wavelet transforms; DVR; Hilbert transform; dynamic voltage restorer; instantaneous reactive power theory; transient power quality disturbances; voltage disturbance detection; voltage sags; wavelet transform; Harmonic analysis; Power quality; Power system harmonics; Reactive power; Wavelet transforms;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Intelligent Control and Information Processing (ICICIP), 2010 International Conference on
  • Conference_Location
    Dalian
  • Print_ISBN
    978-1-4244-7047-1
  • Type

    conf

  • DOI
    10.1109/ICICIP.2010.5564170
  • Filename
    5564170