Abstract :
The Tokamak Cooling Water System (TCWS) Instrumentation and Control (I&C) components of ITER will be located in areas of relatively high magnetic fields. Previous tests on electrical and I&C components have indicated that shielding will be required to protect these components from such magnetic fields. To accomplish this, studies were performed by AREVA Federal Services (AFS) in support of the TCWS Design project with the intent of identifying an optimal solution for shielding I&C components. This paper presents a summary of these studies and presents design options for providing magnetic shielding to ITER TCWS I&C components and electrical equipment that are susceptible to the magnetic fields present.
Keywords :
Tokamak devices; fusion reactor instrumentation; magnetic shielding; plasma toroidal confinement; ITER TCWS control components; ITER TCWS instrumentation; TCWS design project; electrical component shielding; high magnetic fields; magnetic shielding; tokamak cooling water system electrical components; Contracts; Electromagnetic compatibility; Magnetic noise; Magnetic shielding; Silicon carbide; Switches; Tokamaks; Tokamak instrumentation; electromagnetic compatibility; magnetic shielding; stray magnetic fields;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Fusion Engineering (SOFE), 2011 IEEE/NPSS 24th Symposium on
Conference_Location :
Chicago, IL
ISSN :
1078-8891
Print_ISBN :
978-1-4577-0669-1
Electronic_ISBN :
1078-8891
Type :
conf
DOI :
10.1109/SOFE.2011.6052270
Filename :
6052270
Link To Document :
بازگشت