• DocumentCode
    1949884
  • Title

    Mapping of EMG signal to hand grip force at varying wrist angles

  • Author

    Sidek, Shahrul Na´im ; Mohideen, A.J.H.

  • Author_Institution
    Mechatron. Eng. Dept., IIUM, Kuala Lumpur, Malaysia
  • fYear
    2012
  • fDate
    17-19 Dec. 2012
  • Firstpage
    648
  • Lastpage
    653
  • Abstract
    Limb loss is a growing problem in Malaysia and the rest of the world due to the increasing number of industrial accidents, diseases and armed conflicts. After a tragic incident resulting in an amputation or paralysis, the disabled individual needs to be assisted with all possible technological means to improve his quality of life. A cybernetic prosthesis is a device which can greatly assist individuals with hand disabilities by enabling them to have some of the hand capabilities of an able bodied individual. The central nervous system which consists of the brain and spine governs hand grip force and hand movement in the human body by spatial and temporal motor unit recruitments. Electromyogram (EMG) is an electrical biological signal that can be measured from the skin surface and consists of the summation of Motor Unit Action Potentials (MUAP). Hand grip strength, wrist extension and wrist flexion are hand functions which result from the forearm muscle activity and are used in a wide range of daily tasks. Extracting hand grip force and wrist angle information from forearm EMG signals is useful to be used as inputs for the control of cybernetic prostheses. By establishing the relationship between forearm EMG and hand grip force/wrist angles, the prosthetic hand can be controlled in a manner that is customized to an amputee´s intent. In this research work, a myoelectric interface which consists of an electronic conditioning circuit to measure EMG signals and the software to record and process the EMG signals was developed. Experimental training and testing data sets from five subjects were collected to investigate the relationship between forearm EMG, hand grip force and wrist angle simultaneously.
  • Keywords
    biomechanics; bone; electromyography; handicapped aids; manipulator dynamics; medical robotics; medical signal processing; neuromuscular stimulation; prosthetics; EMG signal mapping; Malaysia; amputation; armed conflicts; brain; central nervous system; cybernetic prosthesis; disabled individual; diseases; electrical biological signal; electromyogram; electronic conditioning circuit; experimental training; forearm muscle activity; hand disabilities; hand grip force; hand movement; industrial accidents; limb loss; motor unit action potentials; myoelectric interface; paralysis; skin surface; spine; testing data sets; wrist angles; wrist extension; wrist flexion; Electromyogram; artificial neural networks; hand grip force; wrist angles; wrist extension; wrist flexion;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Biomedical Engineering and Sciences (IECBES), 2012 IEEE EMBS Conference on
  • Conference_Location
    Langkawi
  • Print_ISBN
    978-1-4673-1664-4
  • Type

    conf

  • DOI
    10.1109/IECBES.2012.6498069
  • Filename
    6498069