Title :
The microwave autodyne Gunn oscillator as a simple detector of EPR signal for food-irradiation dosimeter
Author :
Francik, Andrzej
Author_Institution :
Inst. of Telecommun. & Acoust., Tech. Univ. Wroclaw, Poland
Abstract :
A microwave autodyne Gunn oscillator has been presented The oscillator may be used as a simple detector of EPR signal for irradiation-food dosimeter. The idea of EPR method of measurement of radiation dose has been described A low-cost, simple EPR spectrometer for estimation of dose of food irradiation can be built on the basis of microwave autodyne Gunn oscillator. The re-entrant resonator Gunn oscillator has been proposed as an attractive solution of autodyne circuit. The design expressions and the oscillator parameters have been given and one particular oscillator elaborated.
Keywords :
Gunn oscillators; dosimeters; food processing industry; microwave oscillators; paramagnetic resonance; EPR signal detector; food-irradiation dosimeter; microwave autodyne Gunn oscillator; oscillator parameters; radiation dose; re-entrant resonator; Detectors; Electromagnetic wave absorption; Electrons; Gunn devices; Magnetic fields; Magnetic resonance; Microwave oscillators; Paramagnetic resonance; Signal detection; Spectroscopy;
Conference_Titel :
Microwaves, Radar and Wireless Communications, 2002. MIKON-2002. 14th International Conference on
Print_ISBN :
83-906662-5-1
DOI :
10.1109/MIKON.2002.1017816