    Ultrasound tomography dedicated to ANAtomical breast inspection

  • Author

    Rouyer, Julien ; Mensah, Serge ; Lasaygues, Philippe ; Lefebvre, Jean-Pierre

  • Author_Institution
    Lab. of Mech. & Acoust., Nat. Center of Sci. Res., Marseille, France
  • fYear
    2010
  • fDate
    11-14 Oct. 2010
  • Firstpage
    2340
  • Lastpage
    2343
  • Abstract
    The main goal of ultrasound tomography (UT) is to provide both a high contrast imaging and a multi-parametric imaging. Within the frame of soft-tissue imaging, we focus our application to breast inspection for early stage cancer detection. Conforming with breast anatomy, ANAIS (ANAtomical Imaging and Interventional System) prototype is designed including a semicircular antenna which enables imaging of ductolobular structures sensitive to cancer initiation. The 200-mm diameter half-ring transducer contains 1024 elements with 3-MHz center frequency and 2.25-MHz (-6 dB) bandwidth. Chirp excitation is used to improve contrast with pulse compression method. Performed with a needle hydrophone, calibration studies yield system characteristics such as field distribution or transducer element localization. Taking advantage of a near field reconstruction algorithm, tomographic images of thin wire and of breast anthropomorphic phantom (CIRS) are presented. The low frequency approach and the high density of the ring antenna provide interesting results that, as we expect, may still be enhanced.
  • Keywords
    antennas; biomedical transducers; biomedical ultrasonics; cancer; chirp modulation; gynaecology; medical image processing; phantoms; ultrasonic imaging; ultrasonic transducers; anatomical breast inspection; anatomical imaging; bandwidth 2.25 MHz; breast anatomy; breast anthropomorphic phantom; breast inspection; cancer detection; cancer initiation; chirp excitation; ductolobular structures; frequency 3 MHz; half-ring transducer; high-contrast imaging; interventional system prototype; multiparametric imaging; near field reconstruction algorithm; needle hydrophone; ring antenna; semicircular antenna; size 200 mm; soft-tissue imaging; tomographic images; transducer element localization; ultrasound tomography; Acoustics; Breast; Image coding; Image reconstruction; Tomography; Ultrasonic imaging; Ultrasound; breast; imaging; reflection tomography;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium (IUS), 2010 IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1948-5719
  • Print_ISBN
    978-1-4577-0382-9
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2010.5935532
  • Filename
    5935532