Abstract :
Over the past 15 years, comb generators became an indispensable test instrument for EMC labs. Its easy operation led to a wide variety of application like intercomparison measurements of EMC test houses, cable loss measurements and radiated emission system check. The popularity of comb generators should not hide the fact that only the proper measurement know-how can avoid erroneous results. High pulse energy, broadband spectrum and limited frequency accuracy have to be considered when setting the measurement parameters on the EMI-receiver or spectrum analyzer. Good measurement practice is presented by example of cable loss calibration and system check for quality assurance in an EMC lab. The advantage of using an antenna coupler for the system check compared to the monopole antenna is a better repeatability and therefore a more reliable detection of defects (like a broken antenna or cable) in the receive path.
Keywords :
antennas; electromagnetic compatibility; electromagnetic interference; spectral analysers; EMC lab; EMI-receiver; antenna coupler; cable loss calibration; comb generator measurement; quality assurance; spectrum analyzer; system check; Antenna measurements; Electromagnetic compatibility; Energy measurement; Frequency; Instruments; Loss measurement; Measurement techniques; Pulse measurements; Receiving antennas; System testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility and Electromagnetic Ecology, 2007 7th International Symposium on
Conference_Location :
Saint-Petersburg
Print_ISBN :
978-1-4244-1270-9
Electronic_ISBN :
978-1-4244-1270-9
Type :
conf
DOI :
10.1109/EMCECO.2007.4371688
Filename :
4371688
Link To Document :
بازگشت