Three dimensional perfusion imaging in the rat kidney using ultrasound contrast
Author
Feingold, Steven ; Gessner, Ryan ; Gurarcar, Ismayil ; Dayton, Paul A.
Author_Institution
Dept. of Biomed. Eng., Univ. of North Carolina, Chapel Hill, NC, USA
fYear
2010
fDate
11-14 Oct. 2010
Firstpage
1019
Lastpage
1022
Abstract
Recently, there has been great interest in the use of ultrasound contrast to generate quantitative information about tissue perfusion. Using low MI pulse sequences and a clearance - refill approach, it is possible to create quantitative time-to-refill maps of tissue correlating to blood perfusion rate. One limitation of 2D perfusion imaging is that only information from a single slice of tissue is gathered. Vascular inhomogeneity, common in many tumor types, makes perfusion estimates inconsistent unless the same region is imaged repeatedly. Our objective was to evaluate errors in 2D quantitative in-vivo perfusion estimates due to differences in transducer positioning compared to 3D acquisitions. We also examined the effect of contrast dose on perfusion estimates. Destruction-reperfusion imaging was performed with parametric mapping of refill times and image alignment to correct for tissue motion. Images were acquired in rat kidneys using a Siemens Sequoia 512. 3D images were generated by mounting the transducer to a computer controlled linear motion stage. Changes in perfusion times were examined as a function of contrast dose, imaging plane, and in response to the vasoactive drug dopamine. Our results showed that we could differentiate perfusion changes before and after administration of dopamine, and that 3D images were more consistent than 2D acquisitions. We also observed bias caused by contrast agent infusion rate using our time-to-refill algorithm; however, in the range of 2.7 × 108 and 3.9 × 108 bubbles/min the results obtained were consistent to within 3%. 3D perfusion imaging demonstrated a significant reduction in error caused by transducer positioning and improves the reliability of quantitative perfusion time estimates in the rat kidney model.
Keywords
biological tissues; biomedical transducers; biomedical ultrasonics; drugs; haemorheology; kidney; tumours; ultrasonic imaging; 3D acquisitions; Siemens Sequoia 512; blood perfusion rate; contrast dose; destruction-reperfusion imaging; image alignment; linear motion stage; rat kidney; three dimensional perfusion imaging; time-to-refill algorithm; tissue motion; transducer; tumor; ultrasound contrast; vasoactive drug dopamine; Drugs; Imaging; Kidney; Three dimensional displays; Transducers; Tumors; Ultrasonic imaging; 3D; contrast agents; perfusion; ultrasound;
fLanguage
English
Publisher
ieee
Conference_Titel
Ultrasonics Symposium (IUS), 2010 IEEE
Conference_Location
San Diego, CA
ISSN
1948-5719
Print_ISBN
978-1-4577-0382-9
Type
conf
DOI
10.1109/ULTSYM.2010.5935535
Filename
5935535
Link To Document